RACK MOUNTABLE UPS 6-80KVA

Capacity : 6KVA UPTO 80KVA

Categories:

Power Electronics, HR Series Rack Mountable UPS, RACK MOUNTABLE UPS 6-80KVA

  • Specification
  • Features
  • Downloads

 

1PH-1PH/3PH-1PH Hykon HR Series

Model

Hykon HR 11/31 Series

Capacity

6KVA/10KVA (HR 1106/10L) 10KVA/15KVA/20KVA~80KVA (HR 3110/15/20L)

INPUT

 

Nominal Voltage

230 VAC ; 380/400/415 VAC

Operating Voltage Range

120-276 VAC ; 305-478 VAC

Operating Frequency Range

46Hz-54Hz at 50HZ/
56Hz-64Hz at 60HZ

Power Factor

≥0.99

RECTIFIER

IGBT

OUTPUT (INVERTER)

IGBT

Output Voltage

208VAC/220VAC/230VAC/240VAC

AC Volt. Reg. (Batt. Mode)

±1%

Frequency Range

(50/60 ± 0.2) Hz

Crest Factor

3 : 1 (max)

Total Harmonic Distortion

<2% (100% linear load ), <3% (100% nonlinear load )

Transfer Time

AC mode to Batt . Mode

0 ms

Inverter to Bypass

0 ms

Power Factor

0.8

EFFICIENCY

 

Overall

 92%

Inverter

>93%

BATTERY

 

Long - run Model

Battery Voltage

10KVA/240V, 15KVA/240V, 20KVA/240V

Charging Current (max.)

4 A

DISPLAY

I/P V/freq, O/P V/freq, Battery V, Load Watts/VA value & percent, Inverter temperature, Operation mode such as online, on battery or on bypass

INDICATIONS

Green LED for normal operation, Yellow LED for warning condition, Red led for abnormal operation

ALARM

Input / Low / Fail,
Output Overload,
Over Temperature,
Battery low

PHYSICAL

 

Long - run Model

1U = 1.75" height

6U

ENVIRONMENT

 

Temperature

0° C    ? 40° C

Operational Humidity

0%- 95% (non-condensing)

Noise Level

<45 dB

COMMUNICATION

RS 232, SNMP (optional)

PROTECTION

Lightning & Surge protection
Short circuit & overload protection

   
  •  High Frequency & Double Conversion Online Technology
  • Fully digitized microprocessor control
  • Wide Input Voltage Range
  • LCD Display 
  • Cold Start Function
  • Parallel capacity upto 4 nos
  • Advanced battery management
  • Automatic battery charge in UPS off mode
  • Lightning & surge protection
  • Short circuit & overload protection
  • EMI/RFI noise filter
  • Smart RS 232 communication with monitoring software
  • Optionale SNMP card slot

 

image

Contact