dropdown

Banner
Product

HR Series Rack Mountable UPS

RACK MOUNTABLE UPS 1-3KVA

Capacity : 1KVA UPTO 3KVA

Categories:

Power Electronics, HR Series Rack Mountable UPS, RACK MOUNTABLE UPS 1-3KVA

  • Features
  • Specification
  • Downloads

 

  • High Frequency & Double Conversion Online Technology
  • Fully digitized microprocessor control
  • Wide Input Voltage Range
  • LCD Display 
  • Cold Start Function
  • Advanced battery management
  • Automatic battery charge in UPS off mode
  • Lightning & surge protection
  • Short circuit & overload protection
  • EMI/RFI noise filter
  • Smart RS 232 communication with monitoring software
  • Optionale SNMP card slot

 

 

1PH-1PH Hykon HR Series

Model

Hykon HR 11 Series

Capacity

1KVA, 2KVA, 3KVA (HR 1101/2/3L)

INPUT

 

Nominal Voltage

220VAC - 230VAC

Operating Voltage Range

115±5VAC-295±5VAC

Operating Frequency Range

46Hz-54Hz at 50HZ/
56Hz-64Hz at 60HZ

Power Factor

≥0.98

RECTIFIER

IGBT

OUTPUT ( INVERTER)

IGBT

Output Voltage

208VAC/220VAC/230VAC/240VAC

AC Volt. Reg. (Batt. Mode)

±2%

Frequency Range

(50/60 ± 0.2) Hz

Crest Factor

3 : 1 (max)

Total Harmonic Distortion

<2% (100% linear load ), <3% (100% nonlinear load )

Overload

108%±5%<load ≤ 150%±5% > 30s , 150%±5%<load < 200%±5%> 300ms

Transfer Time

AC mode to Batt . Mode

0 ms

Inverter to Bypass

<4ms

Power Factor

0.8

EFFICIENCY

 

Overall

 90%

Inverter

>92%

BATTERY

 

Long - run Model

Battery Voltage

1KVA/36V, 2KVA/72/96V, 3KVA/72/96V

Charging Curnt. (max.)

5-7 A

DISPLAY

I/P V/freq, O/P V/freq, Battery V, Load Watts/VA value & percent, Inverter temperature, Operation mode such as online, on battery or on bypass

INDICATIONS

Green LED for normal operation, Yellow LED for warning condition, Red led for abnormal operation

ALARM

Input / Low / Fail,
Output Overload,
Over Temperature,
Battery low

PHYSICAL

 

Long - run Model

1U = 1.75" height

1KVA (2U) , 2KVA (2U) , 3KVA (3U), 6KVA (3U), 10KVA (3U)

ENVIRONMENT

 

Temperature

0° C    ? 40° C

Operational Humidity

0%   ? 95% (non-condensing)

Noise Level

<45 dB

COMMUNICATION

RS 232 , SNMP (optional)

PROTECTION

Lightning & Surge protection
Shortcircuit & overload protection

   
image

Contact

Address

Hykon India Limited, Ikkandawarrier Road, Thrissur, Kerala,- 680 001

Phone

0487 - 2444183, 2444163

Fax

0487-2425527

Email

ho@hykonindia.com

Regional Office - Bangalore , Chennai , Hyderabad, Pune