dropdown

Banner
Product

Alpha/Galaxy Series- Online UPS Single phase & Three phase

7.5 - 40 KVA ONLINE UPS 3PH - 1PH

Categories:

Power Electronics, Alpha/Galaxy Series- Online UPS Single phase & Three phase, 7.5 - 40 KVA ONLINE UPS 3PH - 1PH

  • Features
  • Specification
  • Downloads

 

  • Three Phase Input- Single Phase Output ;
  • Power Max in VA - 7.5KVA- 40KVA ;
  • Input Voltage - 330-470 V ;
  • Input Frequency - 50+/-2 Hz ;
  • Output Waveform - Pure Sinewave ;
  • Output Power Factor - 0.8;
  • Output Voltage regulation - +/-1% ;
  • Output Voltage 230V
  • Efficiency- >=88% 

 

3Ph to 1 Ph Hykon Online UPS

Parameters

HYKON AEBTS Series

CAPACITY

AEBTS 7.5KVA, 10KVA, 15KVA.

GEBTS 20KVA,25KVA,30KVA,40KVA,50KVA

TECHNOLOGY

True Online IGBT based microprocessor controlled double conversion technology

INPUT

 

Nominal Voltage

415 V 3 Ø & N

Operating Voltage Range

275-476

Operating Frequency Range

50.1 Hz

Power Factor

> 0.9

Rectifier

Diode rectifier

Rectifier battery charger

Constant voltage constant current (CVCC)

OUTPUT

 

Inverter

IGBT based PWM technology

Output Voltage

220V/ 230V

AC Volt. Reg. (Batt. Mode)

 ± 1%

Frequency Range

50HZ±0.5HZ

Crest Factor

3:1 

Total Harmonic Distortion

<3% (linear load) , <5% (non linear load)

Overload

125% for 10min; 150 % for1min; >150% <200 for 20msec; >200% - Sudden

Transfer Time

AC mode to Battery Mode

0 ms

Inverter to Bypass

4 ms 

Power Factor

0.7, 0.8 (optional)

Isolation transformer

Inbuilt at output 230V/230V 1:1

EFFICIENCY at full load

 

Overall efficiency

>88%

Inverter efficiency

>85%

BATTERY

 

Long - run Model

Battery Type

SMF/TUBULAR

Battery Voltage

7.5KVA/180Vdc , 10KVA/240Vdc, 15KVA/240/360Vdc, 20-50KVA/360V

Charging Current. (max.)

10-15 A

DISPLAY

AC Voltage (INPUT/OUTPUT)
Output load %
DC Voltage, O/P FREQ

INDICATIONS

Mains on,inverter on,battery low,over load,Trip

ALARM

Battery Low, Output Overload & Short Circuit.

ENVIRONMENT

 

Temperature

5  °C - 55  °C

Operational Humidity

Up to 85% RH (Non Condensing)

Noise Level

<60dB AT 1 meter

COMMUNICATION

 

RS 232

To connect to PC through RJ45 jack for monitoring UPS (optional feature)

SNMP

To remotely monitor UPS using IPV4/IPV6 (optional feature)

PROTECTION

RF Filter At Output
MCB at EB Input
Snubber Circuit Across All Semiconductors.
Glass cartridge Fuse on Control Circuits

CERTIFICATIONS

ISO 9001:2015, ISO 14001:2015, ROHS, OHSAS, CE

TESTING STANDARDS

 

EMC

2014/30/EU

Low Voltage

2014/35/EU

     
     

 

image

Contact

Address

Hykon India Limited, Ikkandawarrier Road, Thrissur, Kerala,- 680 001

Phone

0487 - 2444183, 2444163

Fax

0487-2425527

Email

ho@hykonindia.com

Regional Office - Bangalore , Chennai , Hyderabad, Pune

Certification

certification

© 2018 Hykon India Limited. All rights reserved.      Designed by : Tedsys